Exide Inverterz Magic Home UPS and Inverter

Features
- DSP (Digital Signal Processor) based design for more reliability with SMT technology*
- ASIC (Auto Sense Intelligent Control) technology for battery charging, automatically senses battery conditions & adjusts the charging current accordingly
- Extremely Low Harmonics
- Dual State of Charging
- Battery Charging Range in Normal Mode i.e. 100V ~ 280V
- Change Over Time Mains to UPS and vice versa < 10msec
- Pure Sine Wave output wave form same as Mains/Grid Power
- Programmed inbuilt ventilation fan which operates as needed
- Auto smart protection built-up in PCB, such as Short Circuit, Overload, Battery Over-Charge, Battery Low, Heat-up, AC Fuse Trip, Phase Reverse, etc.
- Battery Charging Range in UPS Mode i.e. 180V ~ 260V
- Noiseless Operation
- Tri Colour of LCD display for better user interface*
Specifications
| Product | MAGIC 12V 700VA | MAGIC12V 825VA | MAGIC12V 1050VA | MAGIC 24V 1500VA |
| Output Voltage at No Load | 235V ± 15V AC | 235V ± 15V AC | 235V ± 15V AC | 235V ± 15V AC |
| Output Frequency | 50Hz ± 1Hz | 50Hz ± 1Hz | 50Hz ± 1Hz | 50Hz ± 1Hz |
| Output Wave Form | Square Wave | Square Wave | Square Wave | Square Wave |
| Nominal Battery Voltage | 12V DC | 12V DC | 12V DC | 24V DC |
| Battery Low Cut Off | 10.5V ± 0.2V DC | 10.5V ± 0.2V DC | 10.5V ± 0.2V DC | 21.0V ± 0.4V DC |
| Maximum Charging Current (NC) | 09.5Amp ± 1.5Amp | 10Amp ± 1.5Amp | 17Amp ± 1.5Amp | 17Amp ± 1.5Amp |
| Maximum Charging Current (HC) | 13Amp ± 1.5Amp | 14Amp ± 1.5Amp | 12.5Amp ± 1.5Amp | 12.5Amp ± 1.5Amp |
| Boost Charging Voltage | 14.4V ± 0.2V DC | 14.4V ± 0.2V DC | 14.4V ± 0.2V DC | 28.8V ± 0.4V DC |
| Trickle Charging Voltage | 13.7V ± 0.2V DC | 13.7V ± 0.2V DC | 13.7V ± 0.2V DC | 27.4V ± 0.4V DC |
| Charging Current at 120V Mains Input | 8-10 Amp Charging Current* | 8-10 Amp Charging Current* | 8-10 Amp Charging Current* | 8-10 Amp Charging Current* |
| Changeover Time Mains to Back-up (@ UPS Mode) | ≤ 10 msec | ≤ 10 msec | ≤ 10 msec | ≤ 10 msec |
| Changeover Time Back-up to Mains (@ UPS Mode) | ≤ 10 msec | ≤ 10 msec | ≤ 10 msec | ≤ 10 msec |
| Changeover Time Mains to Back-up (@ Normal Mode) | ≤ 40 msec | ≤ 40 msec | ≤ 40 msec | ≤ 40 msec |
| Changeover Time Back-up to Mains (@ Normal Mode) | ≤ 10 msec | ≤ 10 msec | ≤ 10 msec | ≤ 10 msec |
| Input Voltage Range (@ Normal Mode) | 100V - 290V AC | 100V - 290V AC | 100V - 290V AC | 100V - 290V AC |
| *Depends upon Battery Voltage. |